mortality/aging
• all mice die 8 to 10 weeks after tamoxifen injection due to rapid progression to heart failure; mice appear sick and become inactive a few days before death
|
cardiovascular system
• following tamoxifen treatment, hearts show an irregular alignment of cardiomyocytes, with frequent gaps between cells
|
• amount of polymerized F-actin in cardiomyocytes progressively decreases after tamoxifen treatment
• myofibrils at the intercalated disks are often stretched and fragmented following tamoxifen treatment
• Z disks of cardiomyocytes are misaligned and myofibrils are split 60 days after tamoxifen treatment
• 60 days after tamoxifen treatment, cardiac tissue shows a lower density of myofibrils and a defect in demarcation of Z lines and M lines
|
• 95% of intercalated disks of hearts are enlarged, irregularly shaped, and are thicker 60 days after tamoxifen treatment
• intercalated disks show extensive interdigitation and the presence of lacunae, a widened space at the site of myofibril attachment to the intercalated disks, following tamoxifen treatment
|
• hearts show features of eccentric hypertrophy 2 months after tamoxifen treatment, with dilation of the ventricular chambers
• however, no concentric hypertrophy is seen
|
• mild left ventricle enlargement is seen 1 month after tamoxifen treatment, without significant left atrium remodeling and moderately increased left ventricle mass index
|
• dilation of the ventricular chambers is seen 2 months after tamoxifen treatment
|
• mild fibrosis in subendocardial regions are seen 2 months after tamoxifen treatment
|
• hearts are enlarged 2 months after tamoxifen treatment, with impaired contractility and relaxation
• however, thickening of the free wall is not seen
|
• decrease in left ventricular contractility is seen 21 days after tamoxifen treatment, with a decrease in ejection fraction and mean shortening velocity of circumferential fibers
• contractility and relaxation are moderately altered at 1 month after tamoxifen treatment, however 2 months after tamoxifen treatment, a massive decrease in left ventricle contractility and relaxation are seen, with increased E/Ea ratio, indicating heart failure
|
• contractility and relaxation are moderately altered at 1 month after tamoxifen treatment, however 2 months after tamoxifen treatment, a massive decrease in left ventricle contractility and relaxation are seen, with increased E/Ea ratio, indicating heart failure
|
• heart failure is seen 8 to 10 weeks after tamoxifen treatment
|
muscle
• following tamoxifen treatment, hearts show an irregular alignment of cardiomyocytes, with frequent gaps between cells
|
• amount of polymerized F-actin in cardiomyocytes progressively decreases after tamoxifen treatment
• myofibrils at the intercalated disks are often stretched and fragmented following tamoxifen treatment
• Z disks of cardiomyocytes are misaligned and myofibrils are split 60 days after tamoxifen treatment
• 60 days after tamoxifen treatment, cardiac tissue shows a lower density of myofibrils and a defect in demarcation of Z lines and M lines
|
• 95% of intercalated disks of hearts are enlarged, irregularly shaped, and are thicker 60 days after tamoxifen treatment
• intercalated disks show extensive interdigitation and the presence of lacunae, a widened space at the site of myofibril attachment to the intercalated disks, following tamoxifen treatment
|
• hearts are enlarged 2 months after tamoxifen treatment, with impaired contractility and relaxation
• however, thickening of the free wall is not seen
|
• decrease in left ventricular contractility is seen 21 days after tamoxifen treatment, with a decrease in ejection fraction and mean shortening velocity of circumferential fibers
• contractility and relaxation are moderately altered at 1 month after tamoxifen treatment, however 2 months after tamoxifen treatment, a massive decrease in left ventricle contractility and relaxation are seen, with increased E/Ea ratio, indicating heart failure
|
• contractility and relaxation are moderately altered at 1 month after tamoxifen treatment, however 2 months after tamoxifen treatment, a massive decrease in left ventricle contractility and relaxation are seen, with increased E/Ea ratio, indicating heart failure
|
• Z disks of cardiomyocytes are misaligned 60 days after tamoxifen treatment
|
growth/size/body
• hearts show features of eccentric hypertrophy 2 months after tamoxifen treatment, with dilation of the ventricular chambers
• however, no concentric hypertrophy is seen
|
Mouse Models of Human Disease |
DO ID | OMIM ID(s) | Ref(s) | |
dilated cardiomyopathy | DOID:12930 |
OMIM:PS115200 |
J:135043 |